| Management-Funktionen | |
| Schalter-Typ | Managed | 
| Anschlüsse und Schnittstellen | |
| Anzahl der basisschaltenden RJ-45 Ethernet Ports | 24 | 
| Konsolen-Port | RS-232 | 
| Netzwerk | |
| DHCP client | Ja | 
| IGMP snooping | Ja | 
| Link aggregation | Ja | 
| Unterstützung Datenflusssteuerung | Ja | 
| Vollduplex | Ja | 
| Datenübertragung | |
| Durchgang | up to 75.7 million pps (64-byte packets) Mpps | 
| MAC-Adressentabelle | 10000 Eintragungen | 
| Max. Datenübertragungsrate | 1 Gbit/Sek | 
| Protokolle | |
| Unterstützte Netzwerkprotokolle | RFC 1591 DNS (client); HTML and telnet management; IEEE 802.1ad Q-in-Q (Premium License); IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1v VLAN classification by Protocol and Port; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3x Flow Control; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 792 ICMP; RFC 793 TCP; UDLD (Uni-directional Link Detection); RFC 826 ARP; RFC 854 TELNET; RFC 868 Time Protocol; RFC 951 BOOTP; RFC 1058 RIPv1; RFC 1350 TFTP Protocol (revision 2); RFC 1519 CIDR; RFC 1542 BOOTP Extensions; RFC 2030 Simple Network Time Protocol (SNTP) v4; RFC 2131 DHCP; RFC 2453 RIPv2; RFC 2548 (MS-RAS-Vendor only); RFC 3046 DHCP Relay Agent Information Option; RFC 3576 Ext to RADIUS (CoA only); RFC 3768 VRRP; RFC 4675 RADIUS VLAN & Priority; RFC 3376 IGMPv3 (host joins only); RFC 3973 Draft 2 PIM Dense Mode (Premium License); RFC 4601 Draft 10 PIM Sparse Mode (Premium License); RFC 1981 IPv6 Path MTU Discovery; RFC 2460 IPv6 Specification; RFC 2710 Multicast Listener Discovery (MLD) for IPv6; RFC 2925 Remote Operations MIB (Ping only); RFC 3019 MLDv1 MIB; RFC 3315 DHCPv6 (client only); RFC 3513 IPv6 Addressing Architecture; RFC 3596 DNS Extension for IPv6; RFC 3810 MLDv2 (host joins only); RFC 4022 MIB for TCP; RFC 4113 MIB for UDP; RFC 4251 SSHv6 Architecture; RFC 4252 SSHv6 Authentication;  RFC 4253 SSHv6 Transport Layer; RFC 4254 SSHv6 Connection; RFC 4293 MIB for IP; RFC 4419 Key Exchange for SSH; RFC 4443 ICMPv6; RFC 4541 IGMP & MLD Snooping Switch; RFC 4861 IPv6 Neighbor Discovery; RFC 4862 IPv6 Stateless Address Auto-configuration; RFC 1213 MIB II; RFC 1493 Bridge MIB; RFC 1724 RIPv2 MIB; RFC 1850 OSPFv2 MIB; RFC 2021 RMONv2 MIB; RFC 2096 IP Forwarding Table MIB; RFC 2613 SMON MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB; RFC 2665 Ethernet-Like-MIB; RFC 2668 802.3 MAU MIB; RFC 2674 802.1p and IEEE 802.1Q Bridge MIB; RFC 2737 Entity MIB (Version 2); RFC 2787 VRRP MIB; RFC 2863 The Interfaces Group MIB; RFC 2925 Ping MIB; RFC 2328 OSPFv2 (Premium License); RFC 3101 OSPF NSSA; RFC 2474 DiffServ Precedence, including 8 queues/port; RFC 2597 DiffServ Assured Forwarding (AF); RFC 2598 DiffServ Expedited Forwarding (EF); IEEE 802.1X Port Based Network Access Control; RFC 1492 TACACS+; RFC 2865 RADIUS (client only); RFC 2866 RADIUS Accounting.  | 
| Design | |
| Elektromagnetische Verträglichkeit | FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A | 
| Sicherheit | CSA 22.2 No. 60950; EN 60950/IEC 60950; UL 60950 | 
| Leistung | |
| Eingebauter Prozessor | PowerPC 8540 | 
| Flash-Speicher | 256 MB | 
| Prozessor Taktrate | 666 MHz | 
| RAM-Speicher | 256 MB | 
| Stackable | Ja | 
| Strom | |
| Eingangsspannung | 100-120 / 200-240 VAC V | 
| Stromverbrauch (klassisch) | 204.3 W | 
| Power over Ethernet (PoE) | |
| Energie Über Ethernet (PoE) Unterstützung | Nein | 
| Betriebsbedingungen | |
| Temperaturbereich bei Lagerung | -40 - 70 °C | 
| Temperaturbereich in Betrieb | 5 - 40 °C | 
| Temperaturbereich in Betrieb | 41 - 104 °F | 
| Gewicht & Abmessungen | |
| Gewicht | 7800 g | 
| Weitere Spezifikationen | |
| Abmessungen (BxTxH) | 546.1 x 442.5 x 43.2 mm | 
| Eingangsfrequenz | 50 / 60 Hz | 
| Elektrische Verstärker | The switch automatically adjusts to any voltage between 100-120 and 200-240 volts and either 50 or 60 Hz | 
| Elektromagnetische Immunität | EN 55024, CISPR 24; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; EN 61000-3-2, IEC 61000-3-2; EN 61000-3-3, IEC 61000-3-3 | 
| Energiebedarf | 100 -120 VAC / 200 -240 VAC; 50 /60 Hz. The switch automatically adjusts to any voltage between 100-120 and 200-240 volts and either 50 or 60 Hz  | 
| Gewicht | 17.2 lb. lbs | 
| Latenz | 1000 Mb Latency: < 3.4 µs (FIFO 64-byte packets); 10 Gbps Latency: < 2.4 µs (FIFO 64-byte packets) | 
| Management-Plattform | HP PCM+; HP PCM (included); command-line interface; Web browser; configuration menu | 
| Montage | Telco rack: Mounts in an EIA-standard 19-in. 2-post telco rack or equipment cabinet; horizontal surface mounting only. Rack kit: Rack rails are required for mounting in HP 10000 Series 4-post racks. | 
| Netzteiltyp | 1 x J9269A | 
| Remote-Management | command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C) | 
| Speicher und Prozessor | : Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, packet buffer size: 36 MB QDR SDRAM total (18 MB for 1-GbE & 10-GbE ports), 256 MB compact flash, 256 MB DDR SDRAM | 
| Übertragungstechnik | Wired | 
| Unterstützte Protokolle | RFC 1591 DNS (client); HTML and telnet management RFC 1213 MIB II; RFC 1493 Bridge MIB; RFC 1724 RIPv2 MIB; RFC 1850 OSPFv2 MIB; RFC 2021 RMONv2 MIB; RFC 2096 IP Forwarding Table MIB; RFC 2613 SMON MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB; RFC 2665 Ethernet-Like-MIB; RFC 2668 802.3 MAU MIB; RFC 2674 802.1p and IEEE 802.1Q Bridge MIB; RFC 2737 Entity MIB (Version 2); RFC 2787 VRRP MIB; RFC 2863 The Interfaces Group MIB; RFC 2925 Ping MIB MIBs IP multicast IEEE 802.1ad Q-in-Q (Premium License); IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1v VLAN classification by Protocol and Port; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3x Flow Control; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 792 ICMP; RFC 793 TCP; UDLD (Uni-directional Link Detection); RFC 826 ARP; RFC 854 TELNET; RFC 868 Time Protocol; RFC 951 BOOTP; RFC 1058 RIPv1; RFC 1350 TFTP Protocol (revision 2); RFC 1519 CIDR; RFC 1542 BOOTP Extensions; RFC 2030 Simple Network Time Protocol (SNTP) v4; RFC 2131 DHCP; RFC 2453 RIPv2; RFC 2548 (MS-RAS-Vendor only); RFC 3046 DHCP Relay Agent Information Option; RFC 3576 Ext to RADIUS (CoA only); RFC 3768 VRRP (Premium License); RFC 4675 RADIUS VLAN & Priority RFC 1981 IPv6 Path MTU Discovery; RFC 2460 IPv6 Specification; RFC 2461 IPv6 Neighbor Discovery; RFC 2462 IPv6 Stateless Address Auto-configuration; RFC 2463 ICMPv6; RFC 2710 Multicast Listener Discovery (MLD) for IPv6; RFC 2925 Remote Operations MIB (Ping only); RFC 3019 MLDv1 MIB; RFC 3315 DHCPv6 (client only); RFC 3513 IPv6 Addressing Architecture; RFC 3596 DNS Extension for IPv6; RFC 3810 MLDv2 (host joins only); RFC 4022 MIB for TCP; RFC 4113 MIB for UDP; RFC 4251 SSHv6 Architecture; RFC 4252 SSHv6 Authentication; RFC 4253 SSHv6 Transport Layer; RFC 4254 SSHv6 Connection; RFC 4293 MIB for IP; RFC 4419 Key Exchange for SSH; RFC 4541 IGMP & MLD Snooping Switch IEEE 802.1AB Link Layer Discovery Protocol (LLDP); RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events); RFC 3176 sFlow; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED); SNMPv1/v2c/v3; XRMON Network management General protocols Security IEEE 802.1X Port Based Network Access Control; RFC 1492 TACACS+; RFC 2865 RADIUS (client only); RFC 2866 RADIUS Accounting; Secure Sockets Layer (SSL); SSHv2 Secure Shell IPv6 Device management OSPF RFC 2474 DiffServ Precedence, including 8 queues/port; RFC 2597 DiffServ Assured Forwarding (AF); RFC 2598 DiffServ Expedited Forwarding (EF) RFC 2328 OSPFv2 (Premium License); RFC 3101 OSPF NSSA RFC 3376 IGMPv3 (host joins only); RFC 3973 Draft 2 PIM Dense Mode (Premium License); RFC 4601 Draft 10 PIM Sparse Mode (Premium License)  | 
| Weitere Anschlüsse | 20 auto-sensing 10/100/1000 ports(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T), Media Type: Auto-MDIX, Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only; 4 dual-personality ports, each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers); 4 SFP+ 10-GbE ports, Duplex: full only; 1 RS-232C DB-9 console port |